Manual Part No: 930155-01 MD Electric Fryer
- 20 –
Manual Rev No: 4
Service and Maintenance Instructions
Service and Maintenance Instructions
Service and Maintenance Instructions
Service and Maintenance Instructions (cont.)
Removal of Elements
1)
Drain the fryer of oil and remove the Batter Plate.
2)
Lift up the elements to gain access to the Cover Plate securing screws.
3)
Remove the screws and withdraw the Cover Plate.
4)
With the elements placed back in the tank, undo the supply cables and remove the elements from
the mounting plate.
5)
Replace by reversing the above procedure.
Removal of Micro-Switch
1)
Working from the rear of the appliance, remove the fixing screws securing the upper rear panel and
remove.
2)
Lift up the plastic cover on the micro-switch and remove the wires.
3)
Remove the Batter Plate and lift up the elements to gain access to the two micro-switch securing
screws.
4)
The micro-switch can now be removed.
5)
Replace by reversing the above procedure.
Removal of Operating Thermostat
1)
Drain the fryer of oil and remove the Batter Plate.
2)
Pull off the control knob and remove the control panel, secured by two screws.
3)
Remove the wires from the thermostat (noting their positions).
4)
Remove the thermostat from the control panel, secured by two screws.
5)
Open the compartment door to gain access to the thermostat phial gland nut. Undo the gland nut
and withdraw the phial from the tank.
6)
Replace by reversing the above procedure.
ENSURE THAT THE THERMOSTAT CAPILLARY IS NOT KINKED AND THAT THE PHIAL IS CORRECTLY
LOCATED IN ITS HOLDER.
Removal of Override Thermostat
1)
Drain the fryer of oil and remove the Batter Plate.
2)
Pull off the control knob and remove the control panel, secured by two screws.
3)
Remove the wires from the Override Thermostat (noting their positions).
4)
Open the compartment door to gain access to the Override Thermostat fixing nut and remove
Override Thermostat. Undo the gland and withdraw the phial from the tank.
5)
Replace by reversing the above procedure.
ENSURE THAT THE THERMOSTAT CAPILLARY IS NOT KINKED AND THAT THE PHIAL IS CORRECTLY