Manual Part No: 930155-01 MD Electric Fryer
- 11 –
Manual Rev No: 4
Installation
Installation
Installation
Installation (cont.)
Electric Connection
The connection should be made in electrical conduit, via a fused mains isolator on the wall adjacent to
the appliance. The final connection
MUST be made in flexible conduit so that the connections can be
made at the rear of the appliance before it is moved into position.
ENSURE THAT THE CONDUIT IS
CLEAR OF THE FLOOR WHEN THE APPLIANCE IS IN POSITION.
MLE30F-F
A 230V, 50Hz, 1 Phase Supply is required, made through the 25mm conduit entry at
the rear, suitably fused at an easily accessible fused switch isolator.
MLE60F-F
A 400V, 50Hz, 3 Phase, 4 Wire Supply is required, made through the 25mm conduit
entry at the rear, suitably fused at an easily accessible fused switch isolator.
Checking the Operation
ALTHOUGH EVERY APPLIANCE IS TESTED AND SET BEFORE IT LEAVES THE FACTORY, IT IS
IMPORTANT THAT THE INSTALLER RE-CHECKS CERTAIN FUNCTIONS BEFORE LEAVING THE SITE.
1)
Ensure that there is an adequate amount of oil in the pan, and that the Operating Thermostat is set
to the “
OFF” position.
2)
Switch on the electricity supply at the mains isolating switch, and check the green “Mains
ON” neon
lamp glows.
3)
Switch ON the
ON\OFF switch.
4)
Turn the Thermostat to a low temperature setting – until the amber neon glows.
5)
Pivot the heating element assembly out of the pan and check that the safety micro-switch turns
“
OFF” the electricity supply to the elements (i.e. the amber neon will go out).
6)
Replace the element assembly in the pan and check the elements are activated (i.e. the amber neon
will glow), and the oil temperature rises.
7)
Check that the Thermostat operates correctly.
8)
On completion of the above tests, return the thermostat knob to the “
OFF” position.
9)
Switch “OFF” the electricity supply at the mains isolator switch.
WHEN THE INSTALLATION IS COMPLETE, LEAVE THE INSTRUCTION MANUAL WITH A RESPONSIBLE