NICE5000 User Manual 3 Mechanical and Electrical Installation
- 39 -
Mark
Code
Terminal Name
Function Description
Terminal
Arrangement
CN5 Y1-M1 to
Y4-M4
Relay output
Normally-open (NO), maximum
current and voltage rating: 5 A, 250
VAC
Function set in F5-32 to F5-35
CN5
Y1 M1 Y2 M2
M4
Y4
M3
Y3
CN6 CAN2+
CAN2-
Standby
CANbus
communication
terminal
CAN communication for parallel
control
CN6
CAN2
CAN2
+
-
Table 3-3 Description of indicators on the MCB
Mark
Terminal Name
Function Description
Mod2
Standby
communication
indicator
This indicator blinks (green) when the communication is
normal.
CAN2
Standby
communication
indicator
This indicator is steady on (green) when communication
for parallel/group control is normal, and blinks when the
running in parallel/group mode is normal.
Mod1
HCB communication
indicator
When communication between the MCB and the HCB is
normal, this indicator is on (green).
CAN1
CTB communication
indicator
When communication between the MCB and the CTB is
normal, this indicator is on (green).
X1 to X20 Input signal indicator
This indicator is on when the external input is active.
Y1 to Y6
Output signal indicator This indicator is on when the system output is active.
Note
Do not short J6 during normal use. Other jumpers are used for updating programs, and do not
short them if unnecessary.
3.3 CTB Board (MCTC-CTB)
3.3.1 Dimensions and Installation
The car top board (MCTC-CTB) is the elevator car control board of the NICE5000. It
consists of 8 DI terminals, 1 AI terminal, and 9 relay output terminals (standard: 7). It
communicates with the MCTC-CCB and MCTC-HCB through Modbus.
The following figure shows the appearance and structure and installation method of the
CTB.
Summary of Contents for NICE 5000
Page 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Page 15: ......
Page 16: ...1 Safety Information and Precautions...
Page 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Page 24: ...2 Product Information...
Page 34: ...3 Mechanical and Electrical Installation...
Page 71: ...4 Use of the Commissioning Tools...
Page 79: ...5 System Commissioning and Functions...
Page 99: ...6 Function Code Table...
Page 130: ...6 Function Code Table NICE5000 User Manual 128...
Page 131: ...7 Description of Function Codes...
Page 201: ...8 Troubleshooting...
Page 220: ...8 Troubleshooting NICE5000 User Manual 218...
Page 221: ...9 EMC...
Page 230: ...9 EMC NICE5000 User Manual 228...
Page 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...