7 Description of Function Codes NICE5000 User Manual
- 138 -
process (deceleration process) of the S curve.
F3-03 (F3-07) is the time for the rate to increase from 0 to the value set in F3-02 (F3-05) in
the end jerk segment of the S curve. The larger the value is, the smoother the jerk is.
F3-04 (F3-06) is the time for the rate to decrease from the value set in F3-02 (F3-05) to 0 in
the start jerk segment of the S curve. The larger the value is, the smoother the jerk is.
Figure 7-2 Setting the running curve
t (time)
V (speed)
F3-04
F3-02
F3-03
F3-09
F3-07
F3-05
F3-06
F2-22
F3-00
F3-01
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-08
Special deceleration rate
0.800–1.500
0.900
m/s2
★
It is used to set the deceleration rate in elevator slow-down, inspection, and shaft auto-
tuning.
This parameter is not used during normal running. It is used only when the elevator position
is abnormal or the slow-down signal is abnormal, preventing over travel top terminal or over
travel bottom terminal.
Function Code
Parameter Name
Setting Range Default
Unit
Property
F3-09
Pre-deceleration distance
0–50.0
0.0
mm
★
It is used to set the pre-deceleration distance of the elevator in distance control, as shown in
Figure 7-2.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-10
Re-leveling speed
0.040–0.080
0.040
m/s
★
It is used to set the elevator speed during re-leveling.
This parameter is valid only when the pre-open module (MCTC-SCB-A) is added to
implement the re-leveling function (set in F6-09 Bit2 = 1).
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-11
Inspection speed
0.080–0.630
0.250
m/s
★
Summary of Contents for NICE 5000
Page 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Page 15: ......
Page 16: ...1 Safety Information and Precautions...
Page 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Page 24: ...2 Product Information...
Page 34: ...3 Mechanical and Electrical Installation...
Page 71: ...4 Use of the Commissioning Tools...
Page 79: ...5 System Commissioning and Functions...
Page 99: ...6 Function Code Table...
Page 130: ...6 Function Code Table NICE5000 User Manual 128...
Page 131: ...7 Description of Function Codes...
Page 201: ...8 Troubleshooting...
Page 220: ...8 Troubleshooting NICE5000 User Manual 218...
Page 221: ...9 EMC...
Page 230: ...9 EMC NICE5000 User Manual 228...
Page 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...