3 Mechanical and Electrical Installation NICE5000 User Manual
- 50 -
Terminal
Name
Function
Terminal Wiring
S1
Button for setting the floor address.
Hold down the button to adjust the floor address
(range: 0−56). After you stop pressing, the address
number blinks three times, and therefore the setting
is successful.
S1
CN1
Modbus communication and power supply terminal
Pins 2 and 3 are for Modbus communication. Pins 1
and 4 are for DC power supply.
1 2 3 4
MOD
-
MOD
+
24
V
COM
3.4.6 MCTC-HCB-V1 (6.4-inch Segment LCD Display Board)
Figure 3-10 Appearance, dimensions, and installation method of HCB-V1
184
.6
131
160
105
95
135
Φ4.5
Unit: mm
17.9
14.2
2
MCTC
-HCB
-V
1
1 - Plastic support higher than 1 cm
2 - Self-tapping screw 4-
φ
4.9x30
1
The following table describes the input and output terminals of HCB-V1.
Table 3-11 Input and output terminals of HCB-V1
Terminal
Name
Function
Terminal Wiring
J1
Interface for the up call button and indicator
Pins 2 and 3 are for up call input. Pins 1 and 4 are
power supply for the up call indicator (24 VDC output,
load capacity: 40 mA).
1 2 3 4
Up call indicator
Up call
button
Summary of Contents for NICE 5000
Page 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Page 15: ......
Page 16: ...1 Safety Information and Precautions...
Page 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Page 24: ...2 Product Information...
Page 34: ...3 Mechanical and Electrical Installation...
Page 71: ...4 Use of the Commissioning Tools...
Page 79: ...5 System Commissioning and Functions...
Page 99: ...6 Function Code Table...
Page 130: ...6 Function Code Table NICE5000 User Manual 128...
Page 131: ...7 Description of Function Codes...
Page 201: ...8 Troubleshooting...
Page 220: ...8 Troubleshooting NICE5000 User Manual 218...
Page 221: ...9 EMC...
Page 230: ...9 EMC NICE5000 User Manual 228...
Page 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...