NICE5000 User Manual 7 Description of Function Codes
- 191 -
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FU-18
Input state 1
0–65535
0
-
●
FU-19
Input state 2
0–65535
0
-
●
FU-20
Input state 3
0–65535
0
-
●
FU-22
Input state 5
0–65535
0
-
●
FU-23
Output state 1
0–65535
0
-
●
FU-24
Output state 2
0–65535
0
-
●
FU-25
Output state 3
0–65535
0
-
●
FU-26
Car input state
0–65535
0
-
●
FU-27
Car output state
0–65535
0
-
●
FU-28
Hall sate
0–65535
0
-
●
FU-29
System state 1
0–65535
0
-
●
FU-30
System state 2
0–65535
0
-
●
The following figure shows an example of the displayed input states.
Figure 7-10 Example of input state display
1
2
3
4
5
A
B
C
D
E
F
G
DP
Present signal No
. State of present
signal
Display
Meaning
1
0
Active Inactive
Each segment
indicates a signal
Segment ON: active
Segment OFF: inactive
According to the preceding figure, the currently viewed signal 10 (Inspection down) is
1 (Active); besides signal 10, signals 4 (Safety circuit feedback), 5 (Door lock circuit
feedback), 6 (RUN contactor feedback), 7 (Brake contactor feedback), and 8 (Inspection
signal) are active.
Summary of Contents for NICE 5000
Page 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Page 15: ......
Page 16: ...1 Safety Information and Precautions...
Page 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Page 24: ...2 Product Information...
Page 34: ...3 Mechanical and Electrical Installation...
Page 71: ...4 Use of the Commissioning Tools...
Page 79: ...5 System Commissioning and Functions...
Page 99: ...6 Function Code Table...
Page 130: ...6 Function Code Table NICE5000 User Manual 128...
Page 131: ...7 Description of Function Codes...
Page 201: ...8 Troubleshooting...
Page 220: ...8 Troubleshooting NICE5000 User Manual 218...
Page 221: ...9 EMC...
Page 230: ...9 EMC NICE5000 User Manual 228...
Page 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...