touchscreen. This indicates a movement is active.
8. If homing is successful the homed status graphic at the right side of the
screen will turn green.
9. If homing is not successful, a dialog box appears showing the measured
stroke and the factory set Max. Physical stroke. If the factory set stroke
is correct, check for blockages. If the measured stroke is correct, change
the factory set stroke in the factory settings.
NOTE
Mold-Masters
tester or higher user needs to log in to change the factory
settings.
a)
Measured Stroke – the stroke that was automatically calculated by
the E-Drive during the homing procedure.
b)
Max Stroke – from the last time the homing was done successfully.
c)
Max. Physical Stroke - the stroke that is entered in factory settings
which is used to compare with the Measured Stroke.
10. If the homing operation is successful the Homing required message will
disappear from the alarm status display and the homed graphic will turn
green in color.
5-4
E-Drive Controller User Manual (with Pendant HMI)
SETUP
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.