![Moeller S40-AM-TD Manual Download Page 60](http://html1.mh-extra.com/html/moeller/s40-am-td/s40-am-td_manual_1819281060.webp)
Telecontrol function
block services
57
02/02 AWB27-1300-GB
If station B is a PS416 controller, the number of segments is
adjustable. The standard setting in the application module is
for 512 segments. If you wish to change the number of
available segments on the memory card, refer to the section
entitled “Function block SetMCFileLength” of the manual
“S40 Language Elements for PS4-150/-200/-300 and
PS416” (AWB2700-1306-GB).
If you change the number of available segments, you must
alter the range limit for function block input
“tra_flash_segment” in the variables declaration for the
function block:
section “Default parameters” from page 15.
Figure 10: Service 16: Read variable frame length FLASH/RAM
memory card data
VAR_INPUT
tra_flash_segment : UINT(0..511) ;
(*Adjust the number of segments)
END_VAR
h
If station B is a PS4-300 controller, format the memory
card with a recipe range.
tra_subaddress
tra_
destination_offset
2
0
1
. . . 255
10
30
40
50
60
70
80
90
219
0
20
40
50
60
70
80
90
511
0
30
tra_flash_segment
0
127
tra_variable_length
FLASH memory (PS 4)
RAM memory Card (PS 416)
(512 segments at 128 Byte)
Sub address
Station A
Segment
number
RAM receive data array
Station B
Offset
address