![Moeller S40-AM-TD Manual Download Page 42](http://html1.mh-extra.com/html/moeller/s40-am-td/s40-am-td_manual_1819281042.webp)
Parameter function block
39
02/02 AWB27-1300-GB
Example:
Declaration:
Program:
Address setting
:
VAR
Test_tdata_1
AT%SDB1.1.0.0 ARRAY[1..36]
Test_rdata_1
AT%RDB1.1.0.0 ARRAY[1..36]
END_VAR
CAL abc (
strobe:=;
.
.
TCM_tdata:= Test_tdata_1
TCM_rdata:= Test_rdata_1
.
.
:=modem_notify
)
SDB/RDB 1. 1. 0. 0.
1st station (address 2)
.
.
14th station (address 15)
Line number