9
02/02 AWB27-1300-GB
2 Data Arrays of the Function Blocks
Data exchange principle
Data is exchanged between stations via “byte” type data
arrays. This means that data formatted differently in the
application must be converted prior to entry in the data
array. Conversely, array elements must be converted to the
data format of the application before they can be read.
The following example illustrates data exchange between
a station and two remote partner stations.
The “TCMT1zU2/U5“ function blocks provide all functions,
whilst the “TCMT1zB0“ function block only provides the
basic service “Send/Read Fixed Length Data”.
h
The “z” in the function block designation is the
placeholder for either a = asynchronous or
b = synchronous.