VAP Installation and Provisioning
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual
49
5.4.4
Connecting VAP and Verifying Normal Operation
After the VAP has been mounted on the ceiling continue as follows:
Connect the VAPs RJ-45
VCU
connector to the Ethernet jack leading to the
VCU
via RJ-45
cable supplied with VAP.
When using an external antenna, connect the
Ext. Antenna
SMA connector(s) to the external
antenna(s).
This option must be SW configured via the web GUI
.
(Note: Internal
antenna is enabled by default).
Note: The maximum external antenna gain should not exceed 10 dBi.
Verify that the VAP receives power and connects to the VCU via the LEDs on the unit, both the
GREEN LED and the BLUE LED should be lit.
5.5
Verifying VAP Coverage Area
Verify coverage in the areas, adding and moving VAPs for optimal coverage according to the
principles described in 3.3.
Blue LED
Green LED
VAP RJ-45 VCU
Connector