VCU Monitoring and Configuration
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual
61
Alarm
Description
VCU Faulty
Hardware fault detected in VCU
Over Temperature
Temperature of unit exceeds normal range
Mismatch
VCU service type is different from VAP service type
Channel 1/2 DL RF Pwr Low
DL RF Power is lower by 15dBm (or more) from the Max Expected
Pin.
Note: Channel 2 alarm is not displayed when SISO service is
used.
Channel 1/2 DL RF Pwr High
Input power exceeds the maximum expected Pin by more than 3
dB.
Note: Channel 2 alarm is not displayed when SISO service is
used.
Service Off
User has disabled the service
Overall Status
Indicates Fault (RED) level if there are (unmasked) faults, or
GREEN if there are no faults
7.3
Master VCU RF Parameters
Note: The RF parameters are not displayed for control units functioning as Slave VCUs.
To Access the Service RF Tab
Click the
Config
tab from the main menu bar and then select the Master control unit from the
network topology and click the
RF Parameters
tab. The parameters displayed in RF Parameters
tabs correspond to the selected element. The displayed parameters are similar for MIMO and
SISO service modes, however in SISO mode only the
Channel 1 Pin
parameter is displayed.