- 2 -
MAINTENANCE
Caution:
Be sure to turn off the projector and unplug the power cord
from the wall outlet before you perform any maintenance on
the projector.
Cleaning the air-filter
Clean the air-filter frequently. If the air-filter or ventilation
grille become clogged with dirt or dust, the temperature
inside the projector may rise and the power is shut off . (The
TEMP indicator starts to blink red).
For side air outlet grille
1. To remove the filter cover, press
the ridged area gently, push the
cover in the direction of the
arrow and lift.
2. Remove the air-filter from the
filter cover.
3. Wash the air-filter.
• Use water or a mild detergent
diluted with water to clean the
air-filter. Rinse the air-filter
thoroughly and let it dry
completely.
4. Attach the air-filter to the cover.
5. Reinstall the filter cover.
Important:
• If the air-filter is damaged or becomes extremely dirty,
contact your dealer for replacement.
Caution:
Be sure to use the projector with an air-filter attached. If not,
dust may get inside the projector, causing a fire or a
breakdown.
Cleaning the projector and the ventilation grille
Use a soft cloth to clean the projector and the ventilation
grille. When the grille become dirty, wipe them with a soft
cloth dampened with a diluted mild detergent, and then wipe
them with a dry cloth.
To protect the surface of the projector from fading or
deteriorating:
• Do not spray insecticide on or inside the projector.
• Do not use benzine or thinner to clean it.
• Do not let rubber or plastic materials come into contact
with the projector.
Cleaning the lens
Use a standard lens-cleaning brush or a piece of lens tissue
dampened with lens cleaning fluid. The lens surface is
fragile. Use only recommended, nonabrasive lens-cleaning
materials. Do not touch the lens with your fingers.
Use the lamp jig to check the performance and operation of
the OPTICAL UNIT with the MAIN PCB ASSY removed.
(Use it mainly when removing dust from the LCD panel.)
Also use it to check each power system when the self-
diagnosis function finds any error such as a power error.
No. : 859C670O40
How to Use
1. Open the Top Case Assy of the product and remove the
MAIN PCB ASSY. (Remove all the connectors on the
MAIN PCB ASSY.)
2. Connect each connector that has been removed from
the MAIN PCB ASSY with the connectors (SA, SD, SF,
SP, SW, SX and SY) on the lamp jig.
3. Turn off the POWER-ON, FAN-ON, and LAMP-ON
switches on the lamp jig.
4. Connect the power cord with the product and turn on the
main power of the product.
5. Turn on the FAN-ON, POWER-ON, and LAMP-ON
switches in order.
6. After the lamp illuminates, check the Optical Unit or the
power systems.
7. After finishing checking, turn off the LAMP-ON switch on
the lamp jig to put out the lamp.
8. Wait for about 2 minutes after the lamp is put out. Turn
off the POWER-ON and FAN-ON switches.
9. Turn off the main power of the product and disconnect
the power cord.
10. Remove the lamp jig and attach the MAIN PCB ASSY
and the Top Case Assy.
HOW TO USE THE LAMP JIG
SF
SD
GG
SE
SA
GW
GZ
GX
GY
FAN_ON
POWER_ON
LAMP_ON
PCB-POWER TEST
Air-filter
Filter cover
Caution:
• The lamp is fragile. If broken, be careful not to cut
yourself with glass fragments.
• The replacement span of the lamp depends on the
environment. For lamps replacement , please contact
your dealer.