The lamp is designed to project the image on the LCD
panels. When the lamp no longer functions, replace it with
a new one.
Caution:
• Do not remove the lamp immediately after using the
projector. Lamp would be very hot.
• When you replace the lamp, press the power button to
power off, then wait for 60 seconds in stand-by mode to
allow the lamp and LCD panels to cool. Turn off the
main switch, unplug the power cord from the outlet, and
wait one hour so that the lamp is cooled to the touch.
• Do not remove the lamp except for replacement.
Careless treatment can cause injury or fire.
• Do not touch the lamp element directly.
• Be sure not to drop the lamp lid screw into the projector.
Also be sure not to insert metal or any flammable
objects, it may cause fire or electric shock. If any objects
are droped inside, please unplug and contact your
dealer.
• Install the lamp securely, failure may cause a fire.
• If the light bulb explodes breaks, some small glass
fragments may fall out through the small cooling grille,
and sticks to the inside of projector or the lamp box.
When taking the lamp out, make sure to turn over the
projector and hold the handle of the lamp box to avoid
injury from the glass fragments.
• Never shake the lamp or hold it in front of your face after
removing the lamp box. The glass fragments may fall out
and cause injuries to your eyes.
1. Invert the projector gently.
2. Loosen the screw (a) of the lamp
lid using a Phillips screwdriver (+),
and remove the lid.
• Remove the lamp cover in the
direction of the arrow as
indicated.
3. Loosen screws (b) using a Phillips
screwdriver (+).
4. Pull up the handle.
5. Pull out the lamp by the handle.
• Pull out the lamp straight upward.
• Pull the lamp out of the projector
slowly. If the lamp is pulled out
quickly,the light bulb will be
broken and glass fragments will
scatter.
• Once the lamp has been
removed, do not spill liquid on it or
do not, place it near flammable
objects or where children can
touch it.
6. Insert the new lamp securely into
the projector body in the right
direction.
7. Put the handle back to the holding
point.
• Make sure that the handle is
locked.
8. Tighten up the screws (b) using a
Phillips screwdriver (+).
9. Tighten up the screw (a) of the
lamp lid using a Phillips
screwdriver (+).
How to reset the operation time
meter
Plug in the power cord, switch on the projector, and reset
the lamp time by pressing the
,
and POWER buttons
simultaneously.
Caution:
• Do not spill liquid on the lamp or do not place it near
flammable objects or where children can touch it. It may
cause injury or fire.
• Be sure that the projector guide is firmly inserted
between the right and left lamp guides.
Important:
• If the 3 buttons are not pressed at the same time, the
lamp time may not be reset.
• Please make sure the TEMP indicator illuminates about
2 seconds and the lamp time has been reset.
• The projector will not turn on if you do not secure the
lamp lid.
• You must reset the operation time meter after you
replace the lamp.
• Do not reset the operation time meter unless the lamp
has been replaced.
Interval of the lamp replacement
The recommended interval of the lamp replacement is
about 1,500-2,000 hours of consecutive use. However, the
replacement interval may be shorter than such hours
depending on the operating conditions. Decreases in the
luminescence and/or the color brightness will also indicate
that the light source lamp needs to be replaced. When the
lamp operation time exceeds the time elapsed until the lamp
shutdown notice*
1
is issued, the indicator will blink green
and red alternately while the lamp is in operation (and while
the lamp is not in operation, the indicator will blink red only).
In addition, the lamp replacement message will appear on
the screen for one minute every time the power is turned on.
When the lamp operation time exceeds the time elapsed
until the lamp shutdown warning*
2
is issued, the
replacement message*
4
will appear on the screen for one
minute every 10 hours of operation. When the lamp
operation time exceeds the time elapsed until the lamp
shutdown*
3
, the projector will automatically shut off for
safety purposes and the power indicator will illuminate red.
The projector can’t start operating again until the lamp is
replaced and the operation timer is reset.
The projector automatically shuts off when the lamp
operation time exceeds the time elapsed until the lamp
shutdown*
3
. It can’t start operating again until the lamp
is replaced and the operation timer is reset.
SL2U
XL2U
*1Time elapsed until the lamp shutdown notice 1,000 Hours
1,500 Hours
*2Time elapsed until the lamp shutdown warning 1,400 Hours
1,900 Hours
*3Time elapsed until the lamp shutdown
1,500 Hours
2,000 Hours
*4Replacement message
LAMP:>1400H
LAMP:>1900H
(These hours are on the condition that the LAMP MODE is set to “STANDARD.”)
• When the LAMP MODE is set to “LOW,” the time
elapsed until the lamp shutdown will extend up to about
2,000 hours for SL2U and up to about 2,500 hours for
XL2U.
LAMP REPLACEMENT
(a)
(b)
(a)
(b)