- 2 -
¢
¢
Adjustment with Microsoft
®
Windows
®
95/98/Me/XP Operating System
1. Starting
1. Start Windows
®
95/98/Me/XP.
2. Double click on the [Accessories] folder.
3. Double click on the [Hyper Terminal] folder.
4. Double click on the [HyperTrm] icon.
2. Hyper Terminal Setting
1. Click on [Properties] in the File menu on the
Hyper Terminal window.
The [Connection Properties] window will open.
Make settings on this window referring to the
table on the right.
2. Click on [Call] in the Communication menu on
the Hyper Terminal window to make the projector
accessible.
3. Adjustment
Type the adjustment command and the adjustment value of the Hyper Terminal window in capital alphanumeric letters, and
press the ENTER key.
4. Writing Adjustment Value
Type the adjustment command and the adjustment value on the Hyper Terminal window in capital alphanumeric letters, and
press the ENTER key.
Note:
This step is not necessary for “ADC offset/gain adjustment,” which is carried out automatically.
5. Closing
Click on the Close button in the upper-right corner of the window to exit the Hyper Terminal.
Close all the opening windows before exiting Windows
®
95/98/Me/XP.
Item
Setting
Connection
Port (COM1-COM4)
Port settings
: Bits per second
9600
: Data bits
8 bit
: Parity
None
: Stop bits
1
: Flow control
None
Settings
: Emulation
VT100
ASCII setup
: ASCII Sending
Send line ends with line feeds
Echo typed characters locally
Line delay
: 1000 milliseconds
Character delay : 10 milliseconds
: ASCII Receiving
Append line feeds to incoming line ends