a
x1
b
x2
- 17 -
13. Removal of LAMP BOX ASSY
1. Remove the Top Case Assy and the Terminal Board
following “1.Removal of TOP CASE ASSY and
SPEAKER”. (Fig. 3-1)
2. Remove the Terminal Assy (MAIN PCB ASSY, INLET
PCB ASSY, and TERMINAL PCB ASSY) following
“4.Removal of TERMINAL ASSY (MAIN PCB ASSY,
INLET PCB ASSY, and TERMINAL PCB ASSY) ”.
(Fig. 3-4)
3. Remove the Optical Unit following “8. Removal of
OPTICAL UNIT”. (Fig. 3-8)
4. Remove the two (
a
) screws and the Lamp Box Assy as
shown in Fig. 3-13.
a
x2
Optical Unit
Lamp Box Assy
Fig. 3-13
Fig. 4-1
Note:
Only service persons are allowed to replace the
Lamp.
Be sure to wear gloves when replacing the lamp.
Scratches and fingerprints on the lamp may cause
damage or breakage of the lamp.
(Removal)
1. Remove the one (
a
) screws and the Power Socket as
shown in Fig. 4-1.
2. Unfasten the two (
b
) catches and the Lamp Support
(R) as shown in Fig. 4-1.
3. Remove Lamp as shown in Fig. 4-1.
(Installation)
1. Install the Lamp in reverse order of the removal
procedure.
Note:
Make sure that the model name, the engraved
marking on the lamp case, and the parts number are
as shown in the table below after replacing the lamp.
REMOVAL OF LAMP
Lamp
Lamp Support
Lamp Case
Power Socket
model name
engraved marking
parts number
SL2U
U
253P158O10
XL1XU
M
449D039O90
XL2U
Engraved marking