207
Selection of operation mode and
operation location
4
(3) Controllability through communication
*1
As set in
Pr. 338 Communication operation command source
and
Pr. 339 Communication speed command source
.
(Refer to page 206)
*2
At occurrence of RS-485 communication error, the inverter cannot be reset from the computer.
*3
Enabled only when stopped by the PU. At a PU stop, PS is displayed on the operation panel. As set in
Pr. 75
PU stop selection
.
(Refer to page 188)
*4
Some parameters may be write-disabled according to the
Pr. 77
Parameter write selection
setting and operating status.
(Refer to page 191)
*5
Some parameters are write-enabled independently of the operation mode and command source presence/absence. When
Pr. 77
= "2", write is
enabled. (Refer to
page 62
for the parameter list)Parameter clear is disabled.
*6
When
Pr. 550 NET mode operation command source selection
= "1" (RS-485 terminals valid) or
Pr. 550 NET mode operation command source selection
=
"9999" and the communication option is not fitted.
*7
When
Pr. 550 NET mode operation command source selection
= "0" (communication option valid) or
Pr. 550 NET mode operation command source selection
= "9999" and the communication option is fitted.
Operation
Location
Condition
(
Pr. 551
Setting)
Operation
Mode
Item
PU
Operation
External
Operation
External/PU
Combined
Operation Mode
1
(
Pr. 79
= "3")
External/PU
Combined
Operation
Mode 2
(
Pr. 79
= "4")
NET Operation
(when RS-485
terminals are
used)
*6
NET Operation
(when
communication
option is used)
*7
Cont
ro
l b
y RS-
485 c
o
mmun
ic
a
tion f
rom PU c
onnec
to
r
2
(PU
connector)
Run command (start)
×
×
×
Run command (stop)
*3
*3
*3
Running frequency
setting
×
×
×
Monitor
Parameter write
*4
×
*5
*4
*4
×
*5
Parameter read
Inverter reset
Except for 2
Run command (start)
×
×
×
×
×
Run command (stop)
*3
*3
*3
*3
*3
Running frequency
setting
×
×
×
×
×
Monitor
Parameter write
×
*5
×
*5
×
*5
×
*5
×
*5
Parameter read
Inverter reset
Cont
rol
b
y c
ommun
ic
ati
on fr
om
RS-
485 t
e
rmin
a
ls
1
(RS-485
terminals)
Run command(start,
stop)
×
×
×
Running frequency
setting
×
×
×
Monitor
Parameter write
*4
×
*5
*4
*4
×
*5
Parameter read
Inverter reset
Except for 1
Run command
(start, stop)
×
×
×
×
*1
×
Running frequency
setting
×
×
×
×
*1
×
Monitor
Parameter write
×
*5
×
*5
×
*5
×
*5
*4
×
*5
Parameter read
Inverter reset
×
×
×
×
*2
×
Cont
rol
by
c
om
m
uni
ca
tion
fr
om
c
om
m
uni
cat
ion opt
ion
⎯
Run command
(start, stop)
×
×
×
×
×
*1
Running frequency
setting
×
×
×
×
×
*1
Monitor
Parameter write
×
*5
×
*5
×
*5
×
*5
×
*5
*4
Parameter read
Inverter reset
×
×
×
×
×
*2
C
on
tro
l c
irc
ui
t
ext
er
nal te
rm
in
als
⎯
Inverter reset
Run command
(start, stop)
×
×
×
*1
Frequency setting
×
×
×
*1
: Enabled,
×
: Disabled, : Some are enabled