Monitor display and monitor output signal
REMARKS
⋅
By setting "0" in
Pr. 52
, the monitoring of output speed to fault display can be selected in sequence by
.
⋅
When the operation panel (FR-DU07) is used, the displayed units are Hz, V and A only and the others are not displayed.
⋅
The monitor set in
Pr. 52
is displayed in the third monitor position. (The output voltage monitor is changed.)
⋅
Note that load meter and motor load factor are displayed in the second monitor (output current).
* The monitor displayed at power-ON is the first monitor. Display the monitor you want to display on the first monitor and hold
down
for 1s. (To return to the output frequency monitor, hold down
for 1s after displaying the output frequency
monitor.)
Example)When
Pr. 52
is set to "20" (cumulative energization time), the monitor is displayed on the operation panel as described
below.
(2) Display set frequency during stop
(Pr. 52)
⋅
When
Pr. 52
is set to "100", the set frequency
monitor is displayed during a stop and the output
frequency monitor is displayed during operation.
(LED of Hz flickers during stop and is lit during
running.)
When
Pr.52
="100", the set frequency displayed at a
stop indicates frequency to be output when the start
command is ON.
Different from the frequency setting based on
displayed when
Pr. 52
="5", the value maximum/
minimum frequency and frequency jump is
displayed.
Pr. 52
0
100
During
running/stop
During
stop
During
running
Output
frequency
Output
frequency
Set
frequency
Output
frequency
Output current
Output current
Output voltage
Output voltage
Fault display
Fault display
REMARKS
⋅
During an error, the output frequency at error occurrence appears.
⋅
During MRS, the values displayed are the same as during a stop.
Initial value
•
Power-ON monitor (first monitor)
•
S
econd monitor
•
Third monitor
•
Fault monitor
With fault
Output current monitor
Output voltage monitor
Output frequency monitor
•
Power-ON monitor (first monitor)
•
S
econd monitor
•
Third monitor
•
Fault monitor
With fault
Output current monitor
Output frequency monitor
Cumulative energization time monitor