2) Simple Check Table for Main Parts
Normal
Between pins 180k-500k
Ω
For dryer fan
For blower fan
For rotor
P4 Between pin1 and pin4
P4 Between pin4 and pin7
Normal
180- 200
Ω
180- 200
Ω
Abnormal
Open
or
short
Connector
P5
P6
P7
Normal
370- 405
Ω
445- 485
Ω
430- 470
Ω
16k- 18k
Ω
Check terminals
Between pin1 and pin4
Between pin1 and pin3
Between pin1 and pin5
Between pin1 and pin3
Abnormal
Open
or
short
Abnormal
Open or short
Detach the connectors (P11,P13), and measure the resistance using a multimeter.
(Component temperature : 10
℃
t o 30
℃
)
Measure the resistance between terminals using a multimeter.
(Winding temperature : 10
℃
t o 30
℃
)
Measure the resistance between terminals using a multimeter.
(Winding temperature : 10
℃
t o 30
℃
)
Detach the connector (P9), and measure the resistance using a multimeter.
(Component temperature : 10
℃
t o 30
℃
)
Normal……47 - 51k
Ω
(P10 between pin3 and pin4)
Abnormal…open or short
Testing Procedure
Component name
Frame
㨯
heater
thermistor
P11, P13
Room temperature
humidity sensor board
P9
Motor
Heater