![Mitsubishi MJ-EZ6CX-S1-IT Service Manual Download Page 18](http://html.mh-extra.com/html/mitsubishi/mj-ez6cx-s1-it/mj-ez6cx-s1-it_service-manual_1809048018.webp)
NG
Replace the power control board.
Replace the power control board.
Replace the blower fan motor.
Replace the operation control board.
Replace the power control board.
OK
OK
OK
OK
NG
NG
NG
NO
OK
OK
OK
OK
OK
Does the blower fan motor
rotate?
NG
YES
YES
NG
YES
YES
NO
OK
OK
NO
NG
NG
NG
OK
OK
Stepping motor (louvre)
does not operate.
NO
Check the float switch.
●
Check if there is no disconnection or
contact failure of the connector (P12) and
connector pins of operation control board.
●
Check the continuity between connecter (P12)
terminals when the water tank is equipped.
Normal … Tank full : open
Empty:short
Replace the float sensor.
Check if there is no disconnection or
contact failure of the connector (P6) and
connector pins of power control board.
Check the resistance of the blower fan
motor.
Normal : Between pin1 and pin5 430-490
ǡ
Abnormal:Between pin1 and pin5 open or short
Insert the connector and
connector pin securely.
Is the swing louvre switch “OFF”?
Check if there is no disconnection or
contact failure of the connector (P8)and
connector pins of power control board.
Check the resistance between connector
pins of the stepping motor.
Normal : Terminal 1-2
Terminal 1-3
Terminal 1-4 342-418
ǡ
Terminal 1-5
Abnormal:Each interval is open or short
Normal
Does the swing direction of
the louvre change to“wide”,
“ front ” , o r ”upward” ?
Replace the stepping motor.
Insert the connector and connector
pin securely if there are any defects.
NO
NO
NO
YES
YES
OK
YES
OK
OK
OK
OK
OK
NO
NG
Does it dehumidify?
YES
Is there any clog or dust on the
filter ?
Does the zeolite rotate?
YES
NO
Clean the filter.
Are any foreign objects caught
in the gear ring?
Does the rotor motor rotate?
Remove the foreign object
from the gear ring.
Check if there is no disconnection or
contact failure of the connector (P7)and
connector pin of power control board.
Check the continuity of the rotor motor.
Normal:Between the pin1 and pin3
2-4 k
Ω
Abnormal:Between pin1 and pin3
Open or short
Check if there is no disconnection or
contact failure of the connector (P14)
and connector pins of the photo
interrupter and power control board.
Insert the connector and
connector pin securely.
OK
NO
Insert the connector and
connector pin securely.
OK
NO
Replace the power control board.
NO Replace the rotor motor.