①
③
④
②
③
③
Water tank
Left case
setscrews
Left case
setscrews
Special screws
Left case
Special screws
Catch
Handle
Filter
cover
Catch
Fitting
Catches (front 2)
Catches (back 1)
Left case
Right case
【
Precautions for disassembly
】
●
Connection should be performed without fail, especially when screws are used for it.
Tighten the screws securely in that case.
●
When the cable tie fixing the lead wire is cut, be sure to replace it with a new one.
●
Removed lead wire should be fixed to a clamper etc. and perform wiring
①
Pull out the water tank from the lower part of the unit
→
(Removing the water tank)
①
Pull out the water tank.
→
(Reference : Removing the water
tank)
②
Raise the handle first. Pull the upper
part of the filter cover toward you,
and then detach the catches (2) to
remove the filter cover.
③
Remove the left case setscrews (5).
④
Remove the left case setscrews (2)
from the bottom of the unit. Detaching
the fitting (1) of the left and right
cases to remove the left case.
→
(Removing the left case)
①
Pull out the water tank.
→
(Reference : Removing the
water tank)
②
Remove the left case.
→
(Reference : Removing the left
case)
③
Detach the catches which fix the
heat exchanger (front 2, back 1) to
remove the heat exchanger.
→
(Removing the heat exchanger)
< Points at reassembly >
Do not catch the lead wire of the room temperature humidity sensor in the drain pan.
When handling the heat exchanger, do not hold the pipe part in order to prevent breaks in the junction.
(1) Removing the water tank
(2) Removing the left case
(3) Removing the heat exchanger
16. Disassembly and Reassembly Hints
Heat exchanger
35
Summary of Contents for MJ-EZ6CX-S1-IT
Page 50: ...Issued in 2010 7 ...