T A B L E   O F   C O N T E N T S

www.frigidaire.com   USA 1-800-944-9044

www.frigidaire.ca   Canada 1-800-265-8352

Use

 & 

Care

of your

Dehumidifier

......................................................

3
3

..............................................................

2

...............................

Operating Instructions......................................... 4-9

Before You Call ................................................... 12
Major Appliance Limited Warranty ........................ 13

 All

 

about the

16120100A12915

Important Safety Instructions
Location
How It Works

11

....................................................

Normal Sounds

4

..........................................

Dehumidifier Features

Care And Cleaning............................................... 10
Storage .............................................................. 10

Summary of Contents for FFAP5033W1

Page 1: ...800 265 8352 Use Care of your Dehumidifier 3 3 2 Operating Instructions 4 9 Before You Call 12 Major Appliance Limited Warranty 13 All about the 16120100A12915 Important Safety Instructions Location How It Works 11 Normal Sounds 4 Dehumidifier Features Care And Cleaning 10 Storage 10 ...

Page 2: ...ke grille discharge area and outlet ports Ensure that any electrical electronic equipment is one yard away from the unit Do not use or store flammable gases near the unit This dehumidifier contains no user serviceable parts Always call an authorized Electrolux servicer for repairs Do not insert or place fingers or objects into the air discharge area or back grille of the unit Do not start or stop ...

Page 3: ...s The coils condense or draw moisture from the air and air flows through the air outlet louvers into the room as dry warm air Moisture removed from air is collected in a bucket on the front of the dehumidifier The Compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping...

Page 4: ...he BUCKET FULL light is on remove the bucket and re install to reset the float switch NOTE Unit must be upright for one hour prior to operating NOTE ELECTRONIC CONTROL Before you begin thoroughly familiarize yourself with the control panel and all its functions as shown below ADJUSTS HUMIDITY DISPLAYS HUMIDITY SETS FAN SPEED TURNS UNIT ON OR OFF PUMP FEATURE CHECK FILTER RESET BUTTON BUCKET FULL I...

Page 5: ...5 increments 5 seconds after you have set the desired humidity the readout will display the actual room humidity If at any time you want to return to the CONTINUOUS Mode pressing the HUMIDITY button will lower the Relative Humidity through 5 decrements until the display reads CO 2 To turn the unit on press the ON OFF button The unit will run in the factory setting of CONTINUOUS and high fan speed ...

Page 6: ...ff in the hours that will be set Delay Stop If the unit is off then selecting Timer will turn the unit on in the hours that will be set Delay Start TIMER setting First press TIMER button then adjust timer setting by tapping or holding the or button to change the delay timer at 0 5 hour increments up to 10 hours then by 1 hour increments up to 24 hours The control will count down the time remaining...

Page 7: ...plug it in again under normal operating conditions If the EC code persists contact your Authorized Frigidaire Service Center 7 2019 Electrolux Home Products Inc All rights reserved 8 To shut the unit down press the ON OFF button Note After a power outage the unit will memorize the last setting and return the unit to the same setting once power is restored Operating Instructions continued 3 If the ...

Page 8: ...ect position 4 If the display reads PU check the following operating conditions a Make sure the pump drain hose is well connected b Check that the hose is not blocked kinked or frozen c Remove and empty the water bucket to check the bucket pickup for blockage of dirt or alge d Turn off the unit and restart it under normal operating conditions e Unplug the unit and plug it in again under normal ope...

Page 9: ...Hose 1 2 12 7 mm or larger be used Make sure there are no kinks or elevations in the hose 3 When a hose is not attached to the drain connector please ensure drain cap is screwed securely to the connector to prevent leakages NOTE Removing Collected Water continued 3 Pump function To connect pump drain hose a Press the tightening ring of drainage joint fig 11 b Keep pressing the grey ring while pull...

Page 10: ...from the unit b Remove the screw as shown in fig 20 c Take out the pump drainage structure and clean the filter at the button of the hose fig 21 d Reinstall the filter and pump drainage structure to the water bucket Storage When unit is not in use unplug and use the cord wrap shown for your model type 1 Filter Clean the filter every two weeks based on normal operating conditions Clean the Water Bu...

Page 11: ...ripping Sound Sound of Rushing Air At the top of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Today s high efficiency compressors may have a high pitched chatter during the dehumidification cycle High pitched Chatter ...

Page 12: ... Room temperature is too low Unit will not operate satisfactorily if the room temperature is below 41 F 5 C See Operating Conditions Refer to causes under DEHUMlDIFIER RUNS TOO MUCH Dehumidifier has been turned on recently This is normal due to refrigerant rushing through the coil Frost will usually disappear within 60 minutes Room Temperature is too low All models will operate satisfactorily at t...

Page 13: ...LAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW BUT NOT LESS THAN ONE YEAR ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIA...