6 - 44
6 - 44
6. HOW TO COMMUNICATE WITH ID TAGS
6.4.8 Fill data
The Fill Data program is a program for initializing the data of an ID tag with specified
data.
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Buffer Memory Name
Setting Contents
U0
\
G0
Command code specification
area (CH1)
H6 (Fill Data)
U0
\
G3
Head address specification
area (CH1)
K0 (Address: 0)
U0
\
G4
Number of processed points
specification area (CH1)
K0 (All data specified)
U0
\
G100
Data storage area (CH1)
K0 (Fill data: 0)
(b) Devices used by user
1. External inputs (commands/data)
Device Application
M1070
Fill Data of ID Tag command
M1071
Fill Data of ID Tag result reception
M1072
Cancel Fill Data of ID Tag command
2. External outputs (verification)
Device Application
M1073
Normal completion during Fill Data of ID Tag
M1074
Module error during Fill Data of ID Tag
M1075
ID communication complete during Fill Data of ID Tag
D1070
Error details storage during Fill Data of ID Tag