4 - 6
4 - 6
4. SETUP AND PROCEDURES PRIOR TO OPERATION
Connect the 24V DC power supply to the power supply of (1) below.
(1) A circuit (class 2 circuit) having a class 2 power supply module in accordance with
UL1310 or a class 2 transformer in accordance with UL1585 as a power supply,
and a maximum voltage of 30Vrms (42.4 peak) or less
Recommended DC power supply
Manufactured by Omron Corporation (small-sized DIN rail installation type)
Model Input
Voltage
Output Capacity
S8VS-03024
100 to 240VAC
24VDC, 1.3A
• While simply corrective action within the RFID interface module is sufficient to
counter the noise superimposed on the power line, the noise to the ground
can be significantly reduced by supplying power via a line filter.
+24VDC
Line filter
0V