6 - 45
6 - 45
6. HOW TO COMMUNICATE WITH ID TAGS
(2) Program example
Initialize output devices
M1070
RST
M1073
RST
M1074
RST
M1075
MOV
K0
D1070
ID instruction execution
<Command code specification >
M1070
X0
X2
X3
X4
X5
MOV
H6
U0\
G0
<Head address specification >
MOV
K0
U0\
G3
<Number of processed points specification >
MOV
K0
U0\
G4
<Fill Data specification
>
MOV
K0
U0\
G100
SET
Y14
RST
M1070
Fill Data
command
Fill Data
normal
completion
Module error
during
Fill Data
Fill Data ID
communication
complete
Error details
during
Fill Data
Fill Data
command
Module
ready
CH1 ID
communication
complete
CH.1 ID
-BUSY
CH1 ID
instruction
complete
CH1 error
detection
CH1 ID
instruction
execution
request
Fill Data
command