11. Diagnostics
This section describes the error indication, the causes and the countermeasures.
Errors are classified into ones displayed on the data setting panel and the others written to the
BFM #29.
11.1 Indication and causes of errors
< Errors displayed o the data setting panel >
The errors shown in the table below are displayed on the data setting panel.
These errors are indicated so that erroneous settings entered using the data setting panel can be
detected and displayed, and are different from the errors (BFM #29 error code) stored in the
FX
2N
-1RM main body.
Error
indication
Causes
Countermeasures
E01
Fixed output patterns had been already generated
by FNC70 to FNC75, and the data of the
corresponding output No. was to be modified or
copied.
Delete the fixed output patterns. Or stop the copy
operation.
E02
When an ON/OFF angle was entered for new
setting or modification, the value entered
overlapped the existing ON/OFF angle.
The same value was entered in the ON angle and
the OFF angle.
The ON/OFF angle data set by an BFM exceeded
the set range. (When data is entered from the data
setting panel, any data outside the set range is not
accepted.)
Enter a correct ON/OFF angle.
E03
When the ON/OFF output was inverted using
FNC50, the ON/OFF data of the corresponding
output had not been set.
Data not created cannot be inverted.
E05
The same output No. was specified for source and
destination while the output was to be copied.
The same output cannot be copied within the
same bank.
E06
A program was inserted while data was already
present in the step No. 7.
Programs of 8 steps or more are not available. If
required, output data to a different output No., and
set "wired OR" outside.
E07
The same bank No. was specified for source and
destination in the batch copy operation for a bank.
The same bank cannot be copied.
E08
The ON/OFF width became 0 by manipulating
FNC62 to FNC65 (batch addition/subtraction of
angle).
Add or subtract a smaller value. Or delete or
modify the existing data.
E09
Data could not be written to the EEPROM due to
an abnormality in the memory.
Replace the unit.
E13
The resolver was not connected while teaching
was performed or the reference angle was set. Or
something was wrong with the cable
(disconnection, etc.).
Turn off the power, and connect the resolver.
Or replace the cable.
E14
An FNC No. not defined yet was entered.
Enter a correct numeric.
E15
An output No. for which a program was not present
was specified while the program was modified in
the RUN mode.
Specify an output No. for which a program is
present.
Summary of Contents for MELSEC-F FX2N-1RM-E-SET
Page 1: ...USER S MANUAL FX2N 1RM E SET PROGRAMMABLE CAM SWITCH...
Page 6: ...iv FX2N 1RM E SET Programmable Cam Switch...
Page 12: ...FX2N 1RM E SET Programmable Cam Switch...
Page 28: ...Introduction 1 1 16 FX2N 1RM E SET Programmable Cam Switch Memo...
Page 30: ...FX2N 1RM E SET Programmable Cam Switch...
Page 36: ...FX2N 1RM E SET Programmable Cam Switch...
Page 42: ...FX2N 1RM E SET Programmable Cam Switch...
Page 46: ...FX2N 1RM E SET Programmable Cam Switch...
Page 50: ...FX2N 1RM E SET Programmable Cam Switch...
Page 64: ...FX2N 1RM E SET Programmable Cam Switch...
Page 80: ...FX2N 1RM E SET Programmable Cam Switch...
Page 112: ...FX2N 1RM E SET Programmable Cam Switch...
Page 114: ...Monitor 9 9 2 FX2N 1RM E SET Programmable Cam Switch Memo...
Page 116: ...FX2N 1RM E SET Programmable Cam Switch...
Page 124: ...FX2N 1RM E SET Programmable Cam Switch...
Page 128: ...FX2N 1RM E SET Programmable Cam Switch...
Page 138: ...FX2N 1RM E SET Programmable Cam Switch Appendix A 10 Memo...