109
Table 6.3 Error Code List for A2ASCPU(S1/S30) and A2USHCPU-S1 (Continue)
Error
Massage
Error
Code
(D9008)
Detailed
Error
Code
(D9091)
CPU
States
Error and Cause
Corrective Action
"MISSING
END INS"
(Checked at
STOP
RUN.)
12
121
STOP
The
END (
)
instruction is not given in
the main program.
Write the
instruction at the
end of the main
program.
122
The
(
)
instruction is not given in
the sub program if the sub
program is set by
parameters.
Write the
instruction at the
end of the sub
program.
123
(1) When subprogram 2
is set by a parameter,
there is no END
(FEND) instruction in
subprogram 2.
(2) When subprogram 2
is set by a parameter,
subprogram 2 has not
been written from a
peripheral device.
124
(1) When subprogram 3
is set by a parameter,
there is no END
(FEND) instruction in
subprogram 3.
(2) When subprogram 3
is set by a parameter,
subprogram 2 has not
been written from a
peripheral device.
"CAN'T
EXECUTE
(P)"
(Checked at
execution of
instruction.)
13
131
STOP
The same device number
is used at two or more
steps for the pointers (P)
and interrupt pointers (I)
used as labels to be
specified at the head of
jump destination.
Eliminate the same
pointer numbers
provided at the
head of jump
destination.
132
Label of the pointer (P)
specified in the the
,
,
,
,
,
or
instruction is
not provided before the
instruction.
Read the error step
using a peripheral
device, check
contents and insert
a jump destination
pointer (P).
END
FEND
END
END
FEND
END
CJ
SCJ
CALL
CALLP
JMP
LEDA/B FCALL
LEDA/BBREAK
END