MDS-A-SVJ
Detector Types/Regeneration Resistors
3.3
Detector Types
Set the etyp value for
in accordance with the following table.
Detector system
Detector
Remarks
(detector type)
resolution
setting
11
22
33
ABZ + WW (with OHM)
25000
25
High-speed serial
25000
25
No setting
High-speed serial
25000
25
25000
25
HA-FH
8000
8
+ w w
(without
10000
10
OHM)
HA-FE
4000
4
HA-ME
4000
4
3.4
Regeneration Resistors Types
Connectable regeneration resistor combinations depend on the servo amp
capacity,
as shown in the following table. Set
to the number
corresponding to the regeneration resistor combination that is connected.
Regenera-
tion
resistor
resis-
tor
MR-RB033
MR-RB064
MR-RB34
C
MR-RB063
2 x
13 600 W 1400
paral-
0
1
52 72 w 1500
0
0
0
2 x
26 144 w 1500
paral-
0
0
4 x
13
288 w
1500
paral-
0
(NOTE)
Standard resistor selection;
0
Possible resistor selection.
Resistor selection:
If the servo is used on a vertical axis, select
resistors of one or two grades higher than the
standard selection.
12
BNP-B3882B