l
Servo Amps
4.4
Servo Amps
A low power supply voltage can limit maximum operating capacity.
The MDS-A-SVJ-OIW
and MDS-A-SVJ-03W (300W) normally have an
instantaneous operating capacity of 300% of the rated motor output
(excluding HA**N motors).
If the power supply voltage is below
however,
the MDS-A-SVJ-03W's maximum instantaneous operating capacity
is limited to
(250% of the
rated output). With this
limitation,
excessive error 1
alarms are liable to occur. To
prevent excessive error 1 alarms,
increase the excessive error detec-
tion range settings (SV023 and SV053).
Note that the
is not thus affected.
MDS-A-SVJ-OlW and MDS-A-SVJ-03W are designed for use with a
single-phase,
power supply.
Never apply a
power
ply. Use of a 200V power supply would damage the amp.
26
BNP-B3882B