MDS-A-SVJ
Parameter Descriptions
SV052
svo54
SV061
SV063
SV064
OD3
Description
Sets position loop gain during special operation, e.g., with
tap,
main axis C-axis interpolation.
Normally sets main axis position loop gain.
Set
with
if SHG control is carried out during
special operation, e.g.. with synchronous tap, main axis C-axis
interpolation.
Set to zero when not in use.
be set to zero.
be set to zero.
Sets excessive error detection range for special operation. e.g.,
absolute position initial setting or at machine end stopper method.
a setting of zero,
excessive error detection does not take
place when the servo is ON during special operation.
be set to zero.
Sets time in ms from start of deceleration control to application
of dynamic braking.
Normally set to same value as
A setting of zero is taken as an input of 2,000 ms.
Set to 1 if dynamic braking is selected without deceleration con-
trol.
Dynamic braking selection takes precedence over position loop step
stopping.
For axes with brakes,
select position loop step stopping or dynamic
braking.
This parameter's time setting must be larger than that of
Sets time taken to stop from maximum rapid traversing speed (RAPID:
axis configuration parameter) following an emergency stop
(caused
by an external emergency stop input, insufficient voltage, or
alarm).
From other speeds, deceleration control takes place in direct pro-
portion to the parameter setting.
Normally set to same value as rapid traverse time constant.
A setting of zero sets position loop step stopping.
Reset NC power
after changing RAPID (axis configuration
parameteri.
Set together with
when SHG control is used.
Set to zero when not in use.
Set together with
if SHG control is used during spe-
cial operation, e.g., with synchronous tap, main axis C-axis
wlation.
Must be set to zero.
Must be set to zero.
Sets output data number of D/A output channel.
Must be set to zero.
Sets output amplification rate of D/A output channel.
Output amplification rate = setting value 256.
A setting of zero is taken as a setting value of 256 (output ampli-
fication rate =
Must be set to zero.
range
200
999
0
5000
999
-32768
32767
BNP-B3882B