7.4.2 PLC Side Settings (GX Works3)
(1) Select [Parameter]-[Module Information] and add RJ71EN71.
[RJ71EN71 (E-E)] - [Port 1 Module Parameter (Ethernet)] - [Basic Settings] - [Own Node Settings]
Item
Set Value
Remarks
IP Address
192.168.4.40
Ethernet unit IP address
Communications by
Network No./Station No.
Enable
Setting Method for Network No. and
Station Number
Not Use IP Address
Network No.
2
Station Number
40
(2) Go to [Parameter] - [Module Information] - [RJ71EN71 (E-E)] - [Port 1 Module Parameter (Ethernet)] -
[Application Settings] - [Network Station No. <-> IP Information] and set the destination network number,
station number, and IP address after setting [Table Conversion System] to [Setting System].*1
Item
Set Value
Remarks
Setting System
Table Conversion System
Network No.
Station
IP Address
Remarks
2
40
192.168.4.40
Set the Ethernet module’s station number and
IP address.
2
1
192.168.4.50
Set the inverter’s station number and IP
address*2.
*1: For QCPU and LCPU, go to [Parameter] - [Network Parameter (Ethernet/CC IE Field)] in GX Works2 and
add Ethernet to the module 1, and apply the settings above under [Station No. <-> IP Information].
*2: Apply settings to all the connected inverters.
For detail, please
refer to the user’s manual of the devices in use.