![Mitsubishi FR-E800 Series Sample Screen Manual Download Page 24](http://html1.mh-extra.com/html/mitsubishi/fr-e800-series/fr-e800-series_sample-screen-manual_1809262024.webp)
24/79
BCN-P5999-1305-1c
5.1.13 Parameter Storage (Recipe) (B-14100)
Outline
This screen is used to back up/restore the parameters of the specified station number with the recipe function.
Description
1.
Displays the axis name of the selected station.
2.
Touch the station to select the station to back up/restore.
3.
Touch the switch to store the parameters of the inverter in the recipe file of the GOT. Displays the
confirmation dialog at the time of execution.
4.
Switches to the previously displayed screen.
5.
Displays the update date and time of the recipe file of the selected station.
6.
Touch the switch to write the parameters stored in the recipe file in the inverter. Displays the confirmation
dialog at the time of execution.
Remarks
4
2
1
5
3
6