49
Electrical installation
Relay output for emergency mode
NOTE
Mark up any junction boxes with warnings for
external voltage.
When the switch (SF1) is in " " mode (emergency mode) the
circulation pump is activated (EB101-GP12).
CAUTION
No hot water is produced when emergency
mode is activated.
The emergency mode relay can be used to activate external
additional heat. Between the port 2 and 4 is closed during
emergency mode. An external thermostat must be connected to
the control circuit (port 4) to control the temperature. Ensure
that the heating medium circulates through the external
additional heating.
E
P
2 3 4
SMO
Externt
X1
External
RC-HY 20/40
RC-HY20/40
X1
If the relay is to be used for control voltage, bridge the supply
from terminal block X1:1 to X1:2 and connect neutral and
control voltage from the external additional heat to X1:0 (N)
and X1:4 (L).
1
0
E
P
2 3 4
SMO
Externt
N
L
X1
External
RC-HY 20/40
RC-HY20/40
X1
<Connection example with HMK60>
Connect the port 2, 4, 6 on X2 terminal on AA7 board on RC-
HY20/40 to the port K1, K2, K3 on X2 terminal on HMK60
respectively.
SMO
6
1
0
PE
HMK60
RC-HY 20/40
RC-HY 20/40
AA7-X2
X1
L N
1
1
0
2 3 4
PE
1 2 3
4
LEK
1 2 3
4
X1
1
1
N
L
0
E
P
2 3 4
-X2
1
12
34
56
2 3 4 5 6
-X1
AA7-X2
X2
X2
X1
M
ERGENCY
RC - HY
RC - HY
F
K1 K2 K3
K1 K2 K3
Summary of Contents for HMK60
Page 2: ...1 2 ...
Page 87: ...85 Technical data Electrical circuit diagram HSB60 ...
Page 88: ...86 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Page 89: ...87 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Page 90: ...88 Technical data RC HY RC HY RC HY ...
Page 93: ...91 Technical data sheet 3 ...
Page 94: ...92 Technical data sheet 4 ...
Page 97: ...95 Technical data sheet 3 ...
Page 98: ...96 Technical data sheet 4 ...
Page 99: ...97 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Page 100: ...98 Technical data sheet 6 ...
Page 101: ......
Page 104: ...1 2 FDCW71VNX FDCW100VNX LEK LEK ...
Page 189: ...85 Technical data Electrical circuit diagram HSB100 ...
Page 190: ...86 Technical data HMK100 RC HY FDCW FDCW FDCW ...
Page 191: ...87 Technical data FDCW FDCW RC HY RC HY RC HY ...
Page 192: ...88 Technical data RC HY RC HY RC HY ...
Page 195: ...91 Technical data sheet 3 ...
Page 196: ...92 Technical data sheet 4 ...
Page 199: ...95 Technical data sheet 3 ...
Page 200: ...96 Technical data sheet 4 ...
Page 201: ...97 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Page 202: ...98 Technical data sheet 6 ...
Page 203: ......
Page 206: ......
Page 277: ...71 Technical data Electrical circuit diagram HSB140 ...
Page 280: ...74 Technical data sheet 3 ...
Page 281: ...75 Technical data sheet 4 ...
Page 284: ...78 Technical data sheet 3 ...
Page 285: ...79 Technical data sheet 4 ...
Page 286: ...80 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Page 287: ...81 Technical data sheet 6 ...