47
ON
OFF
2.5-second OFF
2.5-second OFF
0.5-second ON
0.5-second ON
LED
Blinking →
MUZ-GL09/12/15/18(H)
MUY-GL09/12/15/18NA
Inverter P.C. board
MUZ-GL24NA(H)
MUY-GL24NA
LED
→
Blinking
No.
Symptom
LED indication
Abnormal point/
Condition
Condition
Remedy
16
Outdoor unit
operates.
1-time blink
2.5 seconds OFF
Frequency drop by
current protection
MUZ-GL09/12/15/18
MUY-GL09/12/15/18
When the input current exceeds ap-
proximately 10.5A, compressor fre-
quency lowers.
The unit is normal, but check the
following.
•
Check if indoor filters are clogged.
• Check if refrigerant is short.
• Check if indoor/outdoor unit air
circulation is short cycled.
MUZ-GL24
MUY-GL24
Current from power outlet is nearing
breaker capacity.
17
3-time blink
2.5 seconds OFF
Frequency drop by
high pressure pro-
tection
Temperature of indoor coil thermistor exceeds 131 °F (55°C)
in HEAT mode, compressor frequency lowers.
Frequency drop by
defrosting in COOL
mode
Indoor coil thermistor reads 46°F (8°C) or less in COOL mode,
compressor frequency lowers.
18
4-time blink
2.5 seconds OFF
Frequency drop by
discharge tempera-
ture protection
Temperature of discharge temperature thermistor exceeds
232°F (111°C), compressor frequency lowers.
• Check refrigerant circuit and refrig-
erant amount.
• Refer to 10-5. "Check of LEV".
• Refer to 10-5. "Check of outdoor
thermistors".
19
5-time blink
2.5 seconds OFF
Outside temperature
thermistor protec-
tion
When the outside temperature thermistor shorts or opens,
protective operation without that thermistors is performed.
• Refer to 10-5. Check of outdoor
thermistors.
20
Outdoor unit
operates.
7-time blink
2.5 seconds OFF
Low discharge tem-
perature protection
Temperature of discharge temperature thermistor has been
122°F (50°C) or less for 20 minutes.
• Refer to 10-5. "Check of LEV".
• Check refrigerant circuit and refrig-
erant amount.
21
8-time blink
2.5 seconds OFF
MUZ-GL09/12/15/18
MUY-GL09/12/15/18
PAM protection
PAM: Pulse Ampli-
tude Modulation
The overcurrent flows into PFC (Power factor correction
:IC820) or the Bus-bar voltage reaches 394 V or more, PAM
stops and restarts.
This is not malfunction. PAM pro-
tection will be activated in the fol-
lowing cases:
1 Instantaneous power voltage
drop. (Short time power failure)
2 When the power supply voltage
is high.
MUZ-GL24
MUY-GL24
Zero cross detecting
circuit
Zero cross signal cannot be detected.
• It occurs with following cases.
1 Instantaneous power voltage
drop. (Short time power failure)
2 Distortion of primary voltage
• Refer to 10-5. "Check of power
supply".
22
9-time blink
2.5 seconds OFF
Inverter check mode The connector of compressor is disconnected, inverter check
mode starts.
• Check if the connector of the com-
pressor is correctly connected.
Refer to 10-5. "How to check
inverter/compressor".
NOTE:
1. The location of LED is illustrated at the right figure. Refer to 10-6.1.
2. LED is lit during normal operation.
3. Blinking patterns of this mode differ from the ones of the failure recall mode.
The blinking frequency shows the number of times the LED blinks after every 2.5-second OFF.
(Example) When the blinking frequency is “2”.
OBH733G
Summary of Contents for MUY-GL09NA-U1
Page 9: ...9 5 WIRING DIAGRAM MUZ GL09NA U1 U8 MUZ GL12NA U1 MUZ GL09NA U2 MUZ GL12NA U2 OBH733G ...
Page 10: ...10 MUZ GL09NAH U2 MUZ GL12NAH U2 MUZ GL09NAH U1 U8 MUZ GL12NAH U1 OBH733G ...
Page 11: ...11 MUY GL09NA U1 MUY GL12NA U1 MUY GL09NA U2 MUY GL12NA U2 OBH733G ...
Page 12: ...12 MUZ GL15NA U2 MUZ GL15NA U1 OBH733G ...
Page 13: ...13 MUZ GL15NAH U2 MUZ GL15NAH U1 OBH733G ...
Page 14: ...14 MUY GL15NA U1 MUY GL15NA U2 OBH733G ...
Page 15: ...15 MUZ GL18NA OBH733G ...
Page 16: ...16 MUZ GL18NAH OBH733G ...
Page 17: ...17 MUY GL18NA OBH733G ...
Page 18: ...18 MUZ GL24NA OBH733G ...
Page 19: ...19 MUZ GL24NAH OBH733G ...
Page 20: ...20 MUY GL24NA OBH733G ...
Page 75: ...75 OBH733G ...