24
NOTE
: Refrigerant piping exceeding 25 ft. requires additional refrigerant charge according to the calculation.
Model
Outdoor unit
precharged
Refrigerant piping length (one way): ft.
25
30
40
50
60
70
80
90
100
MUZ-GL18NA
MUZ-GL18NAH
MUY-GL18NA
3 lb. 9 oz.
0
1.08
3.24
5.40
7.56
9.72
11.88
14.04
16.20
Calculation: X oz. = 1.08/5 oz./ft. × (Refrigerant piping length (ft.) - 25)
NOTE
: Refrigerant piping exceeding 33 ft. requires additional refrigerant charge according to the calculation.
Model
Outdoor unit
precharged
Refrigerant piping length (one way): ft.
33
40
50
60
70
80
90
100
MUZ-GL24NA
MUZ-GL24NAH
MUY-GL24NA
4 lb. 3 oz.
0
4.14
10.06
15.98
21.90
27.82
33.74
39.66
Calculation: X oz. = 2.96/5 oz./ft. × (Refrigerant piping length (ft.) - 33)
DATA
7
7-1. PERFORMANCE DATA
1) COOLING CAPACITY
Model
Indoor air
Outdoor intake air DB temperature (˚F)
IWB (˚F)
75
85
95
105
115
TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC
MUZ-GL09NA
MUZ-GL09NAH
MUY-GL09NA
71
11.0 7.6 0.52 10.3 7.1 0.57 9.7
6.6 0.61 9.0
6.2 0.65 8.3
5.7 0.67
67
10.4 8.6 0.49 9.7
8.0 0.54 9.0
7.4 0.59 8.4
6.9 0.62 7.7
6.3 0.65
63
9.8
9.4 0.47 9.1
8.7 0.52 8.5
8.1 0.56 7.7
7.3 0.60 7.0
6.7 0.62
MUZ-GL12NA
MUZ-GL12NAH
MUY-GL12NA
71
14.7 9.4 0.82 13.7 8.7 0.90 12.9 8.2 0.97 12.0 7.6 1.02 11.0 7.0 1.06
67
13.9 10.7 0.77 13.0 10.0 0.85 12.0 9.2 0.92 11.2 8.6 0.98 10.3 7.9 1.02
63
13.1 11.8 0.74 12.1 10.9 0.81 11.3 10.2 0.88 10.3 9.3 0.94 9.4
8.5 0.98
MUZ-GL15NA
MUZ-GL15NAH
MUY-GL15NA
71
17.2 9.7 0.96 16.0 9.1 1.05 15.1 8.5 1.13 14.0 7.9 1.19 12.9 7.3 1.24
67
16.2 11.4 0.91 15.1 10.6 1.00 14.0 9.8 1.08 13.0 9.1 1.14 12.0 8.4 1.20
63
15.3 12.7 0.86 14.1 11.8 0.96 13.2 11.0 1.03 12.0 10.0 1.10 10.9 9.1 1.14
MUZ-GL18NA
MUZ-GL18NAH
MUY-GL18NA
71
22.1 16.2 1.19 20.6 15.2 1.31 19.4 14.3 1.41 18.0 13.3 1.48 16.6 12.2 1.54
67
20.9 18.2 1.13 19.4 16.9 1.24 18.0 15.7 1.34 16.7 14.6 1.42 15.4 13.4 1.49
63
19.6 19.7 1.07 18.2 18.2 1.19 16.9 17.0 1.28 15.4 15.4 1.37 14.0 14.1 1.42
MUZ-GL24NA
MUZ-GL24NAH
MUY-GL24NA
71
27.6 17.0 1.60 25.8 15.9 1.76 24.2 14.9 1.89 22.5 13.9 1.99 20.7 12.8 2.07
67
26.1 19.6 1.51 24.3 18.2 1.67 22.5 16.9 1.80 20.9 15.7 1.91 19.2 14.4 2.00
63
24.5 21.7 1.44 22.7 20.1 1.59 21.2 18.7 1.72 19.2 17.0 1.84 17.6 15.5 1.91
NOTE
: 1. IWB : Intake air wet-bulb temperature
TC : Total Capacity (x10
3
Btu/h)
SHC : Sensible Heat Capacity (x10
3
Btu/h) TPC : Total Power Consumption (kW)
2. SHC is based on 80˚F of indoor Intake air DB temperature.
MUZ-GL09NA MUZ-GL09NAH MUY-GL09NA
MUZ-GL12NA MUZ-GL12NAH MUY-GL12NA
MUZ-GL15NA MUZ-GL15NAH MUY-GL15NA
MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA
MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA
OBH733G
Summary of Contents for MUY-GL09NA-U1
Page 9: ...9 5 WIRING DIAGRAM MUZ GL09NA U1 U8 MUZ GL12NA U1 MUZ GL09NA U2 MUZ GL12NA U2 OBH733G ...
Page 10: ...10 MUZ GL09NAH U2 MUZ GL12NAH U2 MUZ GL09NAH U1 U8 MUZ GL12NAH U1 OBH733G ...
Page 11: ...11 MUY GL09NA U1 MUY GL12NA U1 MUY GL09NA U2 MUY GL12NA U2 OBH733G ...
Page 12: ...12 MUZ GL15NA U2 MUZ GL15NA U1 OBH733G ...
Page 13: ...13 MUZ GL15NAH U2 MUZ GL15NAH U1 OBH733G ...
Page 14: ...14 MUY GL15NA U1 MUY GL15NA U2 OBH733G ...
Page 15: ...15 MUZ GL18NA OBH733G ...
Page 16: ...16 MUZ GL18NAH OBH733G ...
Page 17: ...17 MUY GL18NA OBH733G ...
Page 18: ...18 MUZ GL24NA OBH733G ...
Page 19: ...19 MUZ GL24NAH OBH733G ...
Page 20: ...20 MUY GL24NA OBH733G ...
Page 75: ...75 OBH733G ...