73
OCH670
SW2 setting
1
ON
2 3 4 5 6
Display detail
Explanation for display
Unit
Capacity setting display
Displayed as an outdoor capacity code.
Code
display
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
Outdoor unit setting information
Indoor pipe temperature / Liquid (TH2(1))
Indoor 1
- 39 to 88
Code
display
:
- 39 to 88
(When the temperature is 0
:
or less, “–” and
temperature are displayed by turns.)
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
Indoor room temperature (TH1)
8 to 39
Capacity
Code
100Y
20
125Y
25
140Y
28
Setting details
• The tens digit (Total display for applied setting)
Cooling only
Single phase / 3 phase
Display details
1 : Cooling only
0 :
Single phase
2 :
3-phase
(Example) When the unit is 3-phase and cooling only,
“30” is displayed.
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
Indoor pipe temperature / Cond. / Eva.
(TH5(1))
Indoor 1
- 39 to 88
- 39 to 88
(When the temperature is 0
:
or less, “–” and
temperature are displayed by turns.)
:
- 39 to 88
(When the temperature is 0
:
or less, “–” and
temperature are displayed by turns.)
- 39 to 88
(When the temperature is 0
:
or less, “–” and
temperature are displayed by turns.)
:
:
:
8 to 39
Indoor pipe temperature / Liquid (TH2(2))
Indoor 2
- 39 to 88
Indoor pipe temperature / Cond. / Eva.
(TH5(2))
Indoor 2
- 39 to 88
1
ON
2 3 4 5 6
The number of connected indoor units
Unit
0 to 4
(The number of connected indoor units are dis-
played.)
The black square ( ) indicates a switch position.