6. DISPLAY
6 - 1
6. DISPLAY
MR-D30 has four LED indications. They indicate the following.
POWER
RUN
STO
ERROR
Green
Green
Yellow
Red
LED
Lighting
status
Description
POWER
On
Power is being supplied.
Off
Power is not supplied.
RUN
On
The safety observation function is in activation. STO, SS1, SS2/SOS, or SLS
function is being executed, shutting off normally or observing.
Off
The safety observation function is not in activation because an operation command
of the safety observation function is not inputted or an internal diagnosis error has
occurred.
STO
On
STO function is in activation. The power to the motors is shut off.
Off
STO function is not in activation. The power to the motors is not shut off.
ERROR
On
An error has been detected for MR-D30. (Note)
Blinking
An error has been detected for MR-D30.
Off
An error is not detected in MR-D30.
Note. When MR-D30 is attached to a servo amplifier not supporting MR-D30, "ERROR" turns on. Refer to
section 1.1 for the software version of a servo amplifier that is compatible with MR-D30.
The following shows indication example of each state.
POWER RUN STO ERROR
Servo
amplifier
display
Status Description
Normal
Power off
Power is not supplied.
95._ or Ab
During diagnosis
For the safety observation function control by input
device, execute a fixing-diagnosis at start-up. For the
safety observation function control by network, connect
networks.
Normal
Safety observation
function is not in
activation.
The safety observation function is not in activation.
95._
Safety observation
function is in
activation.
(shut-off)
STO or SS1 functions are in activation.
Normal
Safety observation
function is in
activation.
(observation in
progress)
SLS or SS2/SOS function is in activation.
/
/
Alarm No.
Error has occurred.
An error has been detected. Refer to chapter 7 for error
details. (Note)
Alarm No.
Error has occurred
(watchdog)
Watchdog is occurring due to parts error, such as the
CPU.
( : On, : Blinking, : Off)
Note. When MR-D30 is attached to a servo amplifier not supporting MR-D30, "ERROR" turns on. Refer to section 1.1 for the software
version of a servo amplifier that is compatible with MR-D30.