5. PARAMETERS
5 - 14
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
PSD03
**SDI2
Input device selection DI2
Select an input device to assign to DI2A (CN10A-13) and DI2B (CN10B-13). Setting method is the same as [Pr.
PSD02].
Setting
digit
Explanation
Initial
value
Setting
range
_ _ x x Input device selection DI2
Refer to table 5.3 for setting.
00h 00h
to
07h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.
PSD04
**SDI3
Input device selection DI3
Select an input device to assign to DI3A (CN10A-5) and DI3B (CN10B-5). Setting method is the same as [Pr.
PSD02].
Setting
digit
Explanation
Initial
value
Setting
range
_ _ x x Input device selection DI3
Refer to table 5.3 for setting.
00h 00h
to
07h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.
PSD05
**SDI4
Input device selection DI4
Select an input device to assign to DI4A (CN10A-14) and DI4B (CN10B-14). Setting method is the same as [Pr.
PSD02].
Setting
digit
Explanation
Initial
value
Setting
range
_ _ x x Input device selection DI4
Refer to table 5.3 for setting.
00h 00h
to
07h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.
PSD06
**SDI5
Input device selection DI5
Select an input device to assign to DI5A (CN10A-6) and DI5B (CN10B-6). Setting method is the same as [Pr.
PSD02].
Setting
digit
Explanation
Initial
value
Setting
range
_ _ x x Input device selection DI5
Refer to table 5.3 for setting.
00h 00h
to
07h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.