5. PARAMETERS
5 - 21
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
PSD28
**SDID2 Input device - Fixing-diagnosis execution selection 2 at start-up
Select whether or not to execute a fixing-diagnosis of DI5_ and DI6_ at start-up.
Setting
digit
Explanation
Initial
value
Setting
range
_ _ _ x Fixing-diagnosis execution selection DI5 at start-up
Select whether or not to execute a fixing-diagnosis of DI5_ at start-
up.
0: Not diagnose
1: Diagnose
1h 0h
to
1h
_ _ x _ Fixing-diagnosis execution selection DI6 at start-up
Select whether or not to execute a fixing-diagnosis of DI6_ at start-
up.
0: Not diagnose
1: Diagnose
1h 0h
to
1h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PSD29
**SDOP
Output device - Test pulse execution selection
Select whether or not to diagnose DO1_ to DO4_ by test pulses. Selecting "0" (Not diagnose) will not transmit
the test pulses from DO1_ to DO4_.
Setting
digit
Explanation
Initial
value
Setting
range
_ _ _ x Test pulse diagnosis execution selection DO1
Select whether or not to diagnose DO1_ by test pulses.
0: Not diagnose
1: Diagnose
1h 0h
to
1h
_ _ x _ Test pulse diagnosis execution selection DO2
Select whether or not to diagnose DO2_ by test pulses.
0: Not diagnose
1: Diagnose
1h 0h
to
1h
_ x _ _ Test pulse diagnosis execution selection DO3
Select whether or not to diagnose DO3_ by test pulses.
0: Not diagnose
1: Diagnose
1h 0h
to
1h
x _ _ _ Test pulse diagnosis execution selection DO4
Select whether or not to diagnose DO4_ by test pulses.
0: Not diagnose
1: Diagnose
This digit is available with MR-D30 manufactured in October, 2014
or later.
1h 0h
to
1h