![Mitsubishi Electric -MR-CV User Manual Download Page 92](http://html.mh-extra.com/html/mitsubishi-electric/mr-cv/mr-cv_user-manual_20704092.webp)
90
10 OPTIONS AND PERIPHERAL EQUIPMENT
10.2 Selection example of wires
Wire size selection examples
The following table lists selection examples for 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire).
*1 The alphabetical letters in the table indicate the symbols of the selection example of crimp terminals.
Page 90 Selection example of crimp terminals
*2 When connecting to the terminal block, use the screws included with the terminal block.
*3 The wires are selected based on the largest rated current among the servo motors to be combined.
*4 Use the size of 2 mm
2
for compliance with the IEC/EN/UL/CSA standard.
Selection example of crimp terminals
*1 Cover the crimped part with an insulating tube.
*2 Mounting may not be possible depending on the size of the crimp terminal, so use the recommended product or an equivalent.
Converter unit
Wire [mm
2
]
L1/L2/L3
L11/L21
MR-CV11K
8 (AWG 8): c
1.25 to 2 (AWG 16 to 14): b
MR-CV18K
22 (AWG 4): i
MR-CV30K
38 (AWG 2): h
MR-CV37K
60 (AWG 2/0): d
MR-CV45K
MR-CV55K
80 (AWG 3/0): e
MR-CV11K4
5.5 (AWG 10): f
MR-CV18K4
8 (AWG 8): c
MR-CV30K4
14 (AWG 6): g
MR-CV37K4
22 (AWG 4): a
MR-CV45K4
MR-CV55K4
38 (AWG 2): h
MR-CV75K4
60 (AWG 2/0): d
Symbol
Crimp terminal on the converter unit side
Crimp terminal
Applicable tool
Manufacturer
Body
Head
Die
a
FVD22-8
YF-1
E-4
YNE-38
DH-123
DH-113
JST
b
FVD2-4
YNT-1614
c
FVD8-5
YF-1
E-4
YNE-38
DH-121
DH-111
60-S8
YPT-60N
TD-125
TD-113
YF-1
E-4
YET-60-1
80-10
YPT-150-1
TD-227
TD-214
YF-1
E-4
YET-150-1
f
FVD5.5-5
YNT-1210S
g
FVD14-8
YF-1
E-4
YNE-38
DH-122
DH-112
h
FVD38-8
YF-1
E-4
YNE-38
DH-124
DH-114
i
22-S5
YPT-60N
DH-123
DH-112
YF-1
E-4
YET-60-1