10
1 FUNCTIONS AND CONFIGURATION
1.4 Configuration including peripheral equipment
1.4
Configuration including peripheral equipment
• Equipment other than the converter unit, drive unit and servo motor is optional or a recommended product.
The following is an example using the MR-J5D1-100G4 and MR-CV11K4.
The actual converter unit and drive unit are mounted closely together.
*1 When sharing the power supply of an inductive load such as a cooling fan with the main circuit of the MR-CV_, do not supply the power
from between the MR-CV_ and AC reactor or from the secondary side of the magnetic contactor to the inductive load. Connect the
inductive load on the power supply side beyond the area in the dotted line.
(FR-BLF)
*1
(MCCB)
(MCCB)
R S T
(MC)
(MR-AL-_K)
MR Configurator2
W
L1
L2
L3
V U
E
W V
U E
L+
CN4
CN5
CN1A
CN40A
CN40A
CN2A
CN2A
CN1A
L-
L11
L21
L+
L-
L11
L21
L+
L-
L11
L21
CN1B
CN40B
CN3
Molded-case
circuit breaker
Molded-case
circuit breaker
Line noise filter
Power supply
Personal
computer
Magnetic
contactor
Servo motor
Servo motor
Power regeneration
converter unit
Mounting attachment
Drive unit
Drive unit
Magnetic
contactor
drive output
AC reactor
Controller
Protection
coordination cable
I/O signal
Protection
coordination cable