1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
69
1
[Pr. PD03_Input device selection 1 (*DI1)]
Select the device to be assigned to the input signal of the CN3 connector. The connector pin numbers to be assigned are as
follows.
[Pr. PD03.0-1_Device selection]
Refer to the following table for setting values.
[Pr. PD04_Input device selection 2 (*DI2)]
Select the device to be assigned to the input signal of the CN3 connector. The connector pin numbers to be assigned are as
follows.
[Pr. PD04.0-1_Device selection]
Refer to the following for setting values.
Page 69 [Pr. PD03_Input device selection 1 (*DI1)]
Initial value
Setting range
Ver.
0000000Ah
Refer to the relevant detail No.
Refer to the relevant detail No.
Model
Axis
Connector pin No.
Initially assigned device
MR-JET-_G
CN3-2
LSP
Initial value
Setting range
Ver.
0Ah
Refer to the text
A4
Setting
Input signal device
00
No assigned function
04
PC
0A
LSP
0B
LSN
0D
CDP
22
DOG
40
CDP2
Initial value
Setting range
Ver.
0000000Bh
Refer to the relevant detail No.
Refer to the relevant detail No.
Model
Axis
Connector pin No.
Initially assigned device
MR-JET-_G
CN3-12
LSN
Initial value
Setting range
Ver.
0Bh
Refer to the text
A4
Summary of Contents for MELSERVO MR-JET-G Series
Page 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Page 2: ......
Page 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Page 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Page 163: ......