1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
89
1
[Pr. PF87_Drive recorder - Analog channel setting 1 (DRAC1)]
[Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
Select the data to be assigned to analog channel 1 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] = "0" (automatic setting mode)
Refer to the following table for setting values.
Values not listed below are undefined. Only set the values that are listed in the following table.
Initial value
Setting range
Ver.
00020201h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
201h
Refer to the text
A4
Setting value
Data type
Unit
Category
000
No assigned function
001
Servo motor speed
1 r/min
16-bit data
002
Torque/instantaneous torque
0.1 %
003
Current command
0.1 %
005
Command pulse frequency (speed unit)
1 r/min
007
Droop pulses (1 pulse unit)
1 pulse
008
Speed command
1 r/min
009
Bus voltage
1 V
00C
Effective load ratio
0.1 %
00D
Regenerative load ratio
0.1 %
00E
Position within one-revolution
16 pulse
00F
ABS counter
1 rev
010
Load to motor inertia ratio
0.01 multiplier
011
Torque equivalent to disturbance
0.1 %
012
Overload alarm margin
0.1 %
014
Settling time
1 ms
015
Overshoot amount
1 pulse
021
Servo motor speed (unit of 0.1 r/min)
0.1 r/min
022
Command pulse frequency (speed unit of 0.1 r/min)
0.1 r/min
023
Speed command (unit of 0.1 r/min)
0.1 r/min
024
Torque command
0.1 %
025
Speed limit value
1 r/min
026
Speed limit value (unit of 0.1 r/min)
0.1 r/min
035
Internal temperature of encoder
1 °C
049
Operation mode
1LSB
04C
U-phase current feedback (unit of the rated current)
0.1 %
04D
V-phase current feedback (unit of the rated current)
0.1 %
04E
W-phase current feedback (unit of the rated current)
0.1 %
Summary of Contents for MELSERVO MR-JET-G Series
Page 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Page 2: ......
Page 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Page 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Page 163: ......