1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
[Pr. PD11_Input filter setting (*DIF)]
[Pr. PD11.0_Input signal filter selection]
[Pr. PD12_Function selection D-1 (*DOP1)]
Set the servo motor thermistor to either enabled or disabled.
[Pr. PD12.3_Servo motor thermistor - Enabled/disabled selection]
0: Enabled
1: Disabled
This servo parameter is enabled when a servo motor with a built-in thermistor is used. When a servo motor without a
thermistor is used, the servo parameter is disabled (temperature monitoring disabled/alarm disabled) regardless of the setting
value.
No alarm is detected in motor-less operation.
When the temperature monitoring of the motor thermistor is disabled, "9999 °C" is displayed.
Initial value
Setting range
Ver.
00000007h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
7h
Refer to the text
A4
Setting value
Filtering time [ms]
0
No filter
1
0.500
2
1.000
3
1.500
4
2.000
5
2.500
6
3.000
7
3.500
8
4.000
9
4.500
A
5.000
B
5.500
Initial value
Setting range
Ver.
00000101h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
B2
Summary of Contents for MELSERVO MR-JET-G Series
Page 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Page 2: ......
Page 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Page 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Page 163: ......