1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
71
1
[Pr. PD08_Output device selection 2 (*DO2)]
Select the device to be assigned to the output signal of CN3 connector. The connector pin numbers to be assigned are as
follows.
[Pr. PD08.0-1_Device selection]
Refer to the following for setting values.
Page 70 [Pr. PD07_Output device selection 1 (*DO1)]
[Pr. PD09_Output device selection 3 (*DO3)]
Select the device to be assigned to the output signal of CN3 connector. The connector pin numbers to be assigned are as
follows.
[Pr. PD09.0-1_Device selection]
Refer to the following for setting values.
Page 70 [Pr. PD07_Output device selection 1 (*DO1)]
Initial value
Setting range
Ver.
00000004h
Refer to the relevant detail No.
Refer to the relevant detail No.
Model
Axis
Connector pin No.
Initially assigned device
MR-JET-_G
CN3-9
INP
Initial value
Setting range
Ver.
04h
Refer to the text
A4
Initial value
Setting range
Ver.
00000003h
Refer to the relevant detail No.
Refer to the relevant detail No.
Model
Axis
Connector pin No.
Initially assigned device
MR-JET-_G
CN3-15
ALM
Initial value
Setting range
Ver.
03h
Refer to the text
A4