84
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF80_Drive recorder - Operation condition selection (DRMC)]
[Pr. PF80.0_Drive recorder - Operation mode selection]
0: Automatic setting mode
1: Manual setting mode
When "0" (automatic setting mode) is set, the setting values of [Pr. PF81 Drive recorder - Sampling operation selection] to [Pr.
PF94 Drive recorder - Digital channel setting 4] are disabled. The drive recorder will be activated automatically at the same
time as an alarm occurs.
When obtaining desired analog data from the drive recorder, set this servo parameter to "1" (manual setting mode) to set the
trigger conditions and sampling cycle, and then start sampling with [Pr. PF81.0 Drive recorder - Sampling start selection].
To disable the drive recorder, set [Pr. PF21 Drive recorder switching time setting] to "-1" (drive recorder function disabled).
[Pr. PF80.2-3_Drive recorder - Sampling cycle selection]
Set the sampling cycle of the drive recorder.
When [Pr. PF80.0] is set to "0" (automatic setting mode), the setting value of this servo parameter is disabled.
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Initial value
Setting range
Ver.
00h
Refer to the text
A4
Setting value
8 kHz class
00
Automatic (250
μ
s)
05
250
μ
s
06
500
μ
s
07
1 ms
08
2 ms
09
4 ms
0A
8 ms
0B
16 ms
0C
32 ms
0D
64 ms
0E
128 ms
0F
256 ms
10
512 ms
11
1.024 s
Summary of Contents for MELSERVO MR-JET-G Series
Page 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Page 2: ......
Page 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Page 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Page 163: ......