![Mitsubishi Electric MELSERVO MR-J5-G-N1 Series User Manual Download Page 37](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j5-g-n1-series/melservo-mr-j5-g-n1-series_user-manual_239178037.webp)
3 STRUCTURE
3.2 Switch setting and display of the drive unit
35
3
3.2
Switch setting and display of the drive unit
Switching to the test operation mode and configuring network setting can be done with switches on the drive unit. The network
communication status and alarm status can also be checked on the display (3-digit, 7-segment LED) of the drive unit.
Switches
If a metal screw driver contacts with the conductive areas, the switches may malfunction. Therefore, use an insulated screw
driver instead of the metal screw driver to operate ID setting switches (SW1/SW2) and DIP switches (SW3).
If all the DIP switches (SW3) are turned "ON (up)", the drive unit is switched to the operation mode for manufacturer setting
and "off" will be displayed. The drive unit cannot be used in this mode. Thus, set the DIP switches (SW3) correctly according
to this section.
To apply the settings of all switches, cycle the control circuit power supply or reset the software.
The following explains the ID setting switches (SW1/SW2) and DIP switches (SW3).
Switch identification
■
1-axis drive unit
■
2-axis drive unit
■
3-axis drive unit
1
ON
2 3 4
3-digit, 7-segment LED
DIP switch (SW3)
For manufacturer setting
For manufacturer setting
Test operation select switch (SW3-1)
ID setting switch (upper) (SW1)
ID setting switch (lower) (SW2)
Disabling control axis switch for A-axis (SW3-2)
1
ON
2 3 4
3-digit, 7-segment LED
DIP switch (SW3)
Disabling control axis switch for B-axis (SW3-3)
For manufacturer setting
Test operation select switch (SW3-1)
ID setting switch (upper) (SW1)
ID setting switch (lower) (SW2)
Disabling control axis switch for A-axis (SW3-2)
1
ON
2 3 4
3-digit, 7-segment LED
DIP switch (SW3)
Disabling control axis switch for B-axis (SW3-3)
Disabling control axis switch for C-axis (SW3-4)
Test operation select switch (SW3-1)
ID setting switch (upper) (SW1)
ID setting switch (lower) (SW2)
Disabling control axis switch for A-axis (SW3-2)