74
3 BASIC FUNCTION
3.3 Stroke limit function
Servo parameter list
The settings related to the stroke limit function can be performed directly with the servo parameters. Perform the settings as
required.
Servo parameter Symbol
Name
Outline
PC19.0
*COP6
[AL. 099 Stroke limit
warning] selection
Enable or disable [AL. 099 Stroke limit warning].
When "Disabled" is selected, [AL. 099 Stroke limit warning] does not occur when LSP
(Forward rotation stroke end) or LSN (Reverse rotation stroke end) is off, but the stroke
limit does still stop the operation.
0: Enabled (initial value)
1: Disabled
PD01.2
*DIA1
Input signal
automatic ON
selection
LSP (Forward rotation stroke end) and LSN (Reverse rotation stroke end) can be set to
"Disabled" (use for an external input signal.) or "Enabled" (automatic ON).
Initial value: 0h (Disabled (Use for an external input signal.))
PD03.0-1
*DI1
Device selection
Any input device can be assigned to the CN3-2 pin.
Initial value: 0Ah (LSP (Forward rotation stroke end))
PD04.0-1
*DI2
Device selection
Any input device can be assigned to the CN3-12 pin.
Initial value: 0Bh (LSN (Reverse rotation stroke end))
PD05.0-1
*DI3
Device selection
Any input device can be assigned to the CN3-19 pin.
Initial value: 22h (DOG (Proximity dog))
PD41.2
*DOP4
Limit switch enabled
status selection
0: Limit switch always enabled (initial value)
1: Enabled only for homing mode
PD41.3
*DOP4
Sensor input method
selection
0: Input from servo amplifier (LSP/LSN/DOG) (initial value)
1: Input from controller (C_FLS/C_RLS/C_DOG)
PL08.2
*LIT3
Magnetic pole
detection - Stroke
limit enabled/disabled
selection
Select whether to enable or disable the stroke limit function during magnetic pole
detection.
0: Enabled (initial value)
1: Disabled
Summary of Contents for MELSERVO-JET MR-JET-G-N1 Series
Page 1: ...MR JET User s Manual Function MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Page 2: ......