5 MONITORING
5.2 Checking with MR Configurator2
147
5
5.2
Checking with MR Configurator2
By using this engineering tool, the status of the servo amplifier (including the servo motor speed, torque, and bus voltage) can
be checked.
In the "Display all" function, the analog data signals of the servo amplifier can be displayed in a list and be readily checked. In
the graph function, the monitor signals can be saved with the high-speed sampling cycle, and the change of signals can be
checked when the gains of the servo amplifier are adjusted. In addition, as the I/O monitor displays the status of the I/O
signals of the servo amplifier, the status of the wiring and signals can be checked.
Refer to the following for the signals which can be checked with the "Display all" function and the graph function.
Page 142 Explanation of monitor signals
The signals set in the I/O device are displayed in the I/O monitor display.
"Display all" function
The analog data signals of the servo amplifier can be displayed with the "Display all" function of MR Configurator2. In "Display
all", the status of the servo amplifier can be updated periodically and displayed.
Graph function
The monitor signals of the selected servo amplifier can be measured and displayed in the graph. For setting details, refer to
"Help" of MR Configurator2.
Display method
1.
Open the graph display screen in MR Configurator2.