3 BASIC FUNCTION
3.12 Electromagnetic brake interlock function
When the forced stop deceleration function is not used
When [Pr. PA04.3 Forced stop deceleration function selection] is set to "0" (Forced stop deceleration function
disabled).
■
Turning the servo-on command on/off
Page 94 Turning the servo-on command on/off
■
Turning the quick stop command (from controller) or EM1 (Forced stop 1) on/off
When the off command is inputted, the servo motor is stopped with the dynamic brake and electromagnetic brake.
*1 ON: Electromagnetic brake is not activated
OFF: Electromagnetic brake is activated
■
Alarm occurrence
When an alarm occurs, the servo motor stops using the same method as with the dynamic brake.
Page 90 Stopping with dynamic brake
■
Power off
The same timing chart shown in "Power off" when using the forced stop deceleration function also applies here.
■
Ready-off command from controller
The same timing chart shown in "Ready-off command from controller" when using the forced stop deceleration function,
applies here.
Page 97 Ready-off command from controller
ON
OFF
0 r/min
ON
OFF
(10 ms)
(210 ms)
(210 ms)
(ON)
(OFF)
Dynamic brake
Dynamic brake
+ electromagnetic brake
Servo motor speed
Electromagnetic brake
released
Electromagnetic brake
Base circuit
Operation delay time
of electromagnetic
brake
Disabled
Quick stop command
(from controller) or EM1
(Forced stop 1)
Enabled
(Electromagnetic
brake interlock)
*1
MBR